<!-- keep this as a security measure: #uncomment if the subject should only be modifiable by the listed groups # * Set ALLOWTOPICCHANGE = Main.TWikiAdminGroup,Main.CMSAdminGroup # * Set ALLOWTOPICRENAME = Main.TWikiAdminGroup,Main.CMSAdminGroup #uncomment this if you want the page only be viewable by the listed groups # * Set ALLOWTOPICVIEW = Main.TWikiAdminGroup,Main.CMSAdminGroup,Main.CMSAdminReaderGroup --> ---+ FW updates on DALCO JBOD servers SN F-18.05.101 -104 and F-18.11.176 * This is the latest firmware package: https://downloadcenter.intel.com/de/download/28696/Intel-Server-Mainboard-S2600WT-BIOS-und-Firmware-Update-f-r-EFI?product=88281 * Copy the unzipped files to an usb stick (not in a folder). * Attach the stick to the server. * Start the server and use the EFI SHELL (boot menu F6) * Wait until startup.nsh automatically starts. * Press ENTER * Now it take some minutes to flash the firmware package. * When the server stops @ FRU/SDR selection hit 1 wait again 10 seconds * When it stops in the EFI SHELL press CTRL ALT DEL to reboot * Now it takes ~5 minutes until the BIOS flash has completed * DONE -- Main.NinaLoktionova - 2020-02-14
This topic: CmsTier3
>
WebHome
>
WebPreferences
>
AdminArea2019
>
HardwareCare
>
JBODDalcoStorageServerControllerSupport
>
BIOSUpdate
Topic revision: r1 - 2020-02-14 - NinaLoktionova